Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.442
Filtrar
1.
Sci Rep ; 14(1): 7478, 2024 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553509

RESUMO

This study examined the possibility of estimating cardiac output (CO) using a multimodal stacking model that utilizes cardiopulmonary interactions during general anesthesia and outlined a retrospective application of machine learning regression model to a pre-collected dataset. The data of 469 adult patients (obtained from VitalDB) with normal pulmonary function tests who underwent general anesthesia were analyzed. The hemodynamic data in this study included non-invasive blood pressure, plethysmographic heart rate, and SpO2. CO was recorded using Vigileo and EV1000 (pulse contour technique devices). Respiratory data included mechanical ventilation parameters and end-tidal CO2 levels. A generalized linear regression model was used as the metalearner for the multimodal stacking ensemble method. Random forest, generalized linear regression, gradient boosting machine, and XGBoost were used as base learners. A Bland-Altman plot revealed that the multimodal stacked ensemble model for CO prediction from 327 patients had a bias of - 0.001 L/min and - 0.271% when calculating the percentage of difference using the EV1000 device. Agreement of model CO prediction and measured Vigileo CO in 142 patients reported a bias of - 0.01 and - 0.333%. Overall, this model predicts CO compared to data obtained by the pulse contour technique CO monitors with good agreement.


Assuntos
Anestesia Geral , Adulto , Humanos , Estudos Retrospectivos , Débito Cardíaco/fisiologia , Pressão Sanguínea , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes
2.
Physiol Rep ; 12(6): e15979, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38490814

RESUMO

Postural orthostatic tachycardia syndrome (POTS) is characterized by an excessive heart rate (HR) response upon standing and symptoms indicative of inadequate cerebral perfusion. We tested the hypothesis that during lower body negative pressure (LBNP), individuals with POTS would have larger decreases in cardiac and cerebrovascular function measured using magnetic resonance (MR) imaging. Eleven patients with POTS and 10 healthy controls were studied at rest and during 20 min of -25 mmHg LBNP. Biventricular volumes, stroke volume (SV), cardiac output (Qc), and HR were determined by cardiac MR. Cerebral oxygen uptake (VO2 ) in the superior sagittal sinus was calculated from cerebral blood flow (CBF; MR phase contrast), venous O2 saturation (SvO2 ; susceptometry-based oximetry), and arterial O2 saturation (pulse oximeter). Regional cerebral perfusion was determined using arterial spin labelling. HR increased in response to LBNP (p < 0.001) with no group differences (HC: +9 ± 8 bpm; POTS: +13 ± 11 bpm; p = 0.35). Biventricular volumes, SV, and Qc decreased during LBNP (p < 0.001). CBF and SvO2 decreased with LBNP (p = 0.01 and 0.03, respectively) but not cerebral VO2 (effect of LBNP: p = 0.28; HC: -0.2 ± 3.7 mL/min; POTS: +1.1 ± 2.0 mL/min; p = 0.33 between groups). Regional cerebral perfusion decreased during LBNP (p < 0.001) but was not different between groups. These data suggest patients with POTS have preserved cardiac and cerebrovascular function.


Assuntos
Síndrome da Taquicardia Postural Ortostática , Humanos , Síndrome da Taquicardia Postural Ortostática/diagnóstico por imagem , Pressão Negativa da Região Corporal Inferior , Débito Cardíaco/fisiologia , Circulação Cerebrovascular/fisiologia , Frequência Cardíaca/fisiologia , Pressão Sanguínea/fisiologia
3.
Eur Radiol Exp ; 8(1): 51, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517595

RESUMO

BACKGROUND: To validate pulmonary computed tomography (CT) perfusion in a porcine model by invasive monitoring of cardiac output (CO) using thermodilution method. METHODS: Animals were studied at a single center, using a Swan-Ganz catheter for invasive CO monitoring as a reference. Fifteen pigs were included. Contrast-enhanced CT perfusion of the descending aorta and right and left pulmonary artery was performed. For variation purposes, a balloon catheter was inserted to block the contralateral pulmonary vascular bed; additionally, two increased CO settings were created by intravenous administration of catecholamines. Finally, stepwise capillary occlusion was performed by intrapulmonary arterial injection of 75-µm microspheres in four stages. A semiautomatic selection of AFs and a recirculation-aware tracer-kinetics model to extract the first-pass of AFs, estimating blood flow with the Stewart-Hamilton method, was implemented. Linear mixed models (LMM) were developed to calibrate blood flow calculations accounting with individual- and cohort-level effects. RESULTS: Nine of 15 pigs had complete datasets. Strong correlations were observed between calibrated pulmonary (0.73, 95% confidence interval [CI] 0.6-0.82) and aortic blood flow measurements (0.82, 95% CI, 0.73-0.88) and the reference as well as agreements (± 2.24 L/min and ± 1.86 L/min, respectively) comparable to the state of the art, on a relatively wide range of right ventricle-CO measurements. CONCLUSIONS: CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by referencing the invasive CO. RELEVANCE STATEMENT: Possible clinical applications of CT perfusion for measuring CO could be in acute pulmonary thromboembolism or to assess right ventricular function to show impairment or mismatch to the left ventricle. KEY POINTS: • CT perfusion measures flow in vessels. • CT perfusion measures cumulative cardiac output in the aorta and pulmonary vessels. • CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by using the invasive CO as a reference standard.


Assuntos
Cateterismo de Swan-Ganz , Artéria Pulmonar , Humanos , Suínos , Animais , Débito Cardíaco/fisiologia , Artéria Pulmonar/diagnóstico por imagem , Cateterismo de Swan-Ganz/métodos , Perfusão , Tomografia Computadorizada por Raios X
4.
J Transl Med ; 22(1): 285, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493167

RESUMO

BACKGROUND: Lactate is traditionally recognized as a by-product of anaerobic metabolism. However, lactate is a preferred oxidative substrate for stressed myocardium. Exogenous lactate infusion increases cardiac output (CO). The exact mechanism underlying this mechanism has yet to be elucidated. The aim of this study was to investigate the cardiovascular mechanisms underlying the acute haemodynamic effects of exogenous lactate infusion in an experimental model of human-sized pigs. METHODS: In this randomised, blinded crossover study in eight 60-kg-pigs, the pigs received infusions with one molar sodium lactate and a control infusion of tonicity matched hypertonic saline in random order. We measured CO and pulmonary pressures using a pulmonary artery catheter. A pressure-volume admittance catheter in the left ventricle was used to measure contractility, afterload, preload and work-related parameters. RESULTS: Lactate infusion increased circulating lactate levels by 9.9 mmol/L (95% confidence interval (CI) 9.1 to 11.0) and CO by 2.0 L/min (95% CI 1.2 to 2.7). Afterload decreased as arterial elastance fell by  -1.0 mmHg/ml (95% CI  -2.0 to  -0.1) and systemic vascular resistance decreased by  -548 dynes/s/cm5 (95% CI  -261 to  -835). Mixed venous saturation increased by 11 percentage points (95% CI 6 to 16), whereas ejection fraction increased by 16.0 percentage points (95% CI 1.1 to 32.0) and heart rate by 21 bpm (95% CI 8 to 33). No significant changes in contractility nor preload were observed. CONCLUSION: Lactate infusion increased cardiac output by increasing heart rate and lowering afterload. No differences were observed in left ventricular contractility or preload. Lactate holds potential as a treatment in situations with lowered CO and should be investigated in future clinical studies.


Assuntos
Hemodinâmica , Ácido Láctico , Animais , Débito Cardíaco/fisiologia , Estudos Cross-Over , Frequência Cardíaca , Suínos , Resistência Vascular
5.
J Physiol Sci ; 74(1): 21, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555424

RESUMO

Mean circulatory filling pressure, venous return curve, and Guyton's graphical analysis are basic concepts in cardiovascular physiology. However, some medical students may not know how to view and interpret or understand them adequately. To deepen students' understanding of the graphical analysis, in place of having to perform live animal experiments, we developed an interactive cardiovascular simulator, as a self-learning tool, as a web application. The minimum closed-loop model consisted of a ventricle, an artery, resistance, and a vein, excluding venous resistance. The simulator consists of three modules: setting (parameters and simulation modes), calculation, and presentation. In the setting module, the user can interactively customize model parameters, compliances, resistance, Emax of the ventricular contractility, total blood volume, and unstressed volume. The hemodynamics are calculated in three phases: filling (late diastole), ejection (systole), and flow (early diastole). In response to the user's settings, the simulator graphically presents the hemodynamics: the pressure-volume relations of the artery, vein, and ventricle, the venous return curves, and the stroke volume curves. The mean filling pressure is calculated at approximately 7 mmHg at the initial setting. The venous return curves, linear and concave, are dependent on the venous compliance. The hemodynamic equilibrium point is marked on the crossing point of venous return curve and the stroke volume curve. Users can interactively do discovery learning, and try and confirm their interests and get their questions answered about hemodynamic concepts by using the simulator.


Assuntos
Hemodinâmica , Veias , Animais , Humanos , Veias/fisiologia , Volume Sistólico , Pressão Sanguínea/fisiologia , Débito Cardíaco/fisiologia
6.
Ulus Travma Acil Cerrahi Derg ; 30(2): 90-96, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38305657

RESUMO

BACKGROUND: In critically ill patients, especially those with septic shock, fluid management can be a challenging aspect of clinical care. One of the primary steps in treating patients with hemodynamic instability is optimizing intravascular volume. The Passive Leg Raising (PLR) maneuver is a reliable test for assessing fluid responsiveness, as demonstrated by numerous studies and meta-analyses. However, its use requires the measurement of cardiac output, which is often complex and may necessitate clinician experience and specialized equipment. End-Tidal Carbon Dioxide (ETCO2) measurement is relatively easy and is generally stable under steady metabolic conditions. It depends on the body's CO2 production, diffusion of CO2 from the lungs into the bloodstream, and cardiac output. If the other two parameters (metabolic conditions and minute ventilation) are constant, ETCO2 can provide information about cardiac output. The aim of the present study is to investigate the sensitivity of ETCO2 measurement in demonstrating fluid responsiveness. METHODS: All patients diagnosed with septic shock and meeting the inclusion criteria were subjected to a passive leg raising test, and cardiac outputs were measured by echocardiography. An increase in cardiac output of 15% or more was considered indicative of the fluid responder group, while patients with an increase below 15% or no increase were classified as the non-responder group. Patients' intensive care unit admission diagnoses, initial laboratory parameters, tidal volume, minute volume before and after the PLR maneuver, mean and systolic blood pressure, heart rate, Pulse Pressure Variation (PPV) values, and ETCO2 values were recorded. RESULTS: Before and after the ETCO2 test, there was no statistically significant difference between the two groups. However, the change in ETCO2 (ΔETCO2) was significantly higher in the responder group. In the non-responder group, ΔETCO2 was 2.57% (0.81), whereas it was 5.71% (2.83) in the responder group (p<0.001). Receiver Operating Characteristic (ROC) analysis was performed for ΔETCO2, baseline Stroke Volume Variation (SVV), ΔSVV, baseline Heart Rate (HR), ΔHR, baseline PPV, and ΔPPV to predict fluid responsiveness. ΔETCO2 predicted fluid responsiveness with a sensitivity of 85% and a specificity of 86% when it was 4% or higher. When ΔETCO2 was 5% or higher, it predicted fluid responsiveness with a specificity of 99.3% and a sensitivity of 75.5%, with an Area Under the Curve (AUC) of 0.89 (95% confidence interval, 0.828-0.961). CONCLUSION: This study demonstrates that in septic patients, ETCO2 during the PLR test can indicate fluid responsiveness with high sensitivity and specificity and can be used as an alternative to cardiac output measurement.


Assuntos
Choque Séptico , Humanos , Choque Séptico/diagnóstico , Choque Séptico/terapia , Dióxido de Carbono/metabolismo , Volume Sistólico/fisiologia , Hemodinâmica , Respiração Artificial , Débito Cardíaco/fisiologia , Hidratação/métodos
7.
Am J Obstet Gynecol MFM ; 6(3): 101312, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38342307

RESUMO

BACKGROUND: The physiological changes to the cardiovascular system during pregnancy are considerable and are more pronounced in those with cardiac disease. In the general population, noninvasive hemodynamic monitoring is a valid alternative to pulmonary artery catheterization, which poses risk in the pregnant population. There is limited data on noninvasive cardiac output monitoring in pregnancy as an alternative to pulmonary artery catheterization. OBJECTIVE: We sought to compare transthoracic echocardiography with a noninvasive cardiac output monitor (NICOM, Cheetah Medical) in pregnant patients with and without cardiac disease. STUDY DESIGN: This was a prospective, open-label validation study that compared 2-dimensional transthoracic echocardiography with NICOM estimations of cardiac output in each trimester of pregnancy and the postpartum period. Participants with and without cardiac disease with a singleton gestation were included. NICOM estimations of cardiac output were derived from thoracic bioreactance and compared with 2-dimensional transthoracic echocardiography for both precision and accuracy. A mean percentage difference of ±30% between the 2 devices was considered acceptable agreement between the 2 measurement techniques. RESULTS: A total of 58 subjects were enrolled; 36 did not have cardiac disease and 22 had cardiac disease. Heart rate measurements between the 2 devices were strongly correlated in both groups, whereas stroke volume and cardiac output measurements showed weak correlation. When comparing the techniques, the NICOM device overestimated cardiac output in the control group in all trimesters and the postpartum period (mean percentage differences were 50.3%, 52.7%, 48.1%, and 51.0% in the first, second, and third trimesters and the postpartum period, respectively). In the group with cardiac disease, the mean percentage differences were 31.9%, 29.7%, 19.6%, and 35.2% for the respective timepoints. CONCLUSION: The NICOM device consistently overestimated cardiac output when compared with 2-dimensional transthoracic echocardiography at all timepoints in the control group and in the first trimester and postpartum period for the cardiovascular disease group. The physiological changes of pregnancy, specifically the mean chest circumference and total body water, may alter the accuracy of the cardiac output measurement by the NICOM device as they are currently estimated. Although NICOM has been validated for use in the critical care setting, there is insufficient data to support its use in pregnancy.


Assuntos
Ecocardiografia , Cardiopatias , Gravidez , Feminino , Humanos , Estudos Prospectivos , Débito Cardíaco/fisiologia , Volume Sistólico/fisiologia , Ecocardiografia/métodos
8.
Hypertens Pregnancy ; 43(1): 2310607, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38353244

RESUMO

OBJECTIVES: To assess the ability of the USCOM® (USCOM), using measurements of cardiac output (CO) and systemic vascular resistance (SVR), to predict the development of pre-eclampsia (PE) and severe PE in hypertensive pregnancies. STUDY DESIGN: Prospective cohort study of women in the second or third trimester recruited at a tertiary center in Sydney, Australia. Demographic data and hemodynamic measurements using the USCOM were taken for all study participants at recruitment. Pregnancy outcome, including development of PE and severe PE, was tracked. Data were analyzed using ANOVA testing, pair-wise comparison testing, and Student's t-testing. RESULTS: Recruitment included 65 normotensive controls, 34 women with chronic hypertension (CH), 51 with gestational hypertension (GH), and 21 with PE. Significantly higher weight, body surface area, and blood pressure measurements were found in the hypertensive, compared with the normotensive control and pregnancies. There were no observed differences in USCOM-measured CO, cardiac index, SVR, or systemic vascular resistance index between hypertensive women who did versus did not develop PE or severe PE in later pregnancy. Analysis of the CH and GH subgroups, as well as only unmedicated hypertensive women (n = 24), also showed no significant difference in hemodynamic parameters between those who did or did not develop PE or severe PE. CONCLUSIONS: Our group was unable to successfully predict the onset of PE or severe PE based on hemodynamic parameters measured with the USCOM. It is possible this relates to the high proportion of women on antihypertensive medication at recruitment.


Assuntos
Hipertensão Induzida pela Gravidez , Pré-Eclâmpsia , Gravidez , Feminino , Humanos , Estudos Prospectivos , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia
9.
Eur J Pediatr ; 183(5): 2183-2192, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376594

RESUMO

We aimed to establish reference ranges for USCOM parameters in preterm infants, determine factors that affect cardiac output, and evaluate the measurement repeatability. This retro-prospective study was performed at Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy. We included infants below 32 weeks of gestational age (GA) and/or 1500 g of birth weight (BW). We excluded infants with congenital heart diseases or hemodynamic instability. Measurements were performed at 3 ± 1, 7 ± 2, and 14 ± 2 postnatal days. We analyzed 204 measurements from 92 patients (median GA = 30.57 weeks, BW = 1360 g). The mean (SD) cardiac output (CO) was 278 (55) ml/min/kg, cardiac index (CI) was 3.1 (0.5) L/min/m2, and systemic vascular resistance (SVRI) was 1292 (294) d*s*cm-5/m2. CO presented a negative correlation with postmenstrual age (PMA), while SVRI presented a positive correlation with PMA. The repeatability coefficient was 31 ml/kg/min (12%).  Conclusion: This is the first study describing reference values for USCOM parameters in hemodynamically stable preterm infants and factors affecting their variability. Further studies to investigate the usefulness of USCOM for the longitudinal assessment of patients at risk for cardiovascular instability or monitoring the response to therapies are warranted. What is Known: • The ultrasonic cardiac output monitoring (USCOM) has been widely used on adult and pediatric patients and reference ranges for cardiac output (CO) by USCOM have been established in term infants. What is New: • We established reference values for USCOM parameters in very preterm and very-low-birth-weight infants; the reference ranges for CO by USCOM in the study population were 198-405 ml/kg/min. • CO normalized by body weight presented a significant negative correlation with postmenstrual age (PMA); systemic vascular resistance index presented a significant positive correlation with PMA.


Assuntos
Débito Cardíaco , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Débito Cardíaco/fisiologia , Masculino , Feminino , Valores de Referência , Estudos Prospectivos , Estudos Retrospectivos , Hemodinâmica/fisiologia , Reprodutibilidade dos Testes , Idade Gestacional , Monitorização Fisiológica/métodos , Resistência Vascular/fisiologia
10.
Eur J Pediatr ; 183(4): 1849-1855, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38276999

RESUMO

Clinical parameters used for hemodynamic assessment and titration of vasopressor therapy in neonates with septic shock have several limitations. Functional echocardiography is an emerging tool for bedside assessment of cardiac function and may be useful for diagnosis of shock and assessing the response to therapy. Data regarding echocardiographic parameters in neonates with shock is lacking. This prospective observational study was conducted in a Level III NICU with the primary objective of comparing echocardiographic characteristics of neonates with septic shock at diagnosis, following fluid boluses, and after maximum inotropic support [A1]. Additionally, we compared these characteristics with those of healthy stable neonates who were gestation and postnatal age-matched. A total of 36 neonates with septic shock and 30 gestation and postnatal age-matched controls were enrolled. The mean (SD) gestation and birth weight of neonates with septic shock were 30.6 (4.0) weeks and 1538 (728) g, respectively. Gram-negative bacilli constituted 78.9% of all isolates. At presentation, there was no significant difference between neonates with shock and controls in terms of ventricular outputs, shortening fraction, ratio of early to late diastolic trans-mitral flow velocity, and myocardial performance indices. The distensibility index of inferior vena cava was higher in neonates with shock compared to controls, (17% vs 10%, (p < 0.01)). Left ventricular output was 209 (92) and 227 (102) ml/kg/min (p = 0.53) and right ventricular output was 427 (203) and 459 (227) ml/kg/min, (p = 0.03), respectively, before and after inotropic therapy.     Conclusion: Echocardiographic parameters may not differentiate neonates with septic shock from hemodynamically stable neonates. Neonates with shock associated with predominantly gram-negative sepsis are not able to augment cardiac functions, either at the onset or after administration of inotropes.      Trial registration: (CTRI/2017/12/010766). What is known: • For neonates with shock, echocardiography is becoming increasingly popular as an objective method of evaluating hemodynamics. • In healthy preterm neonate, cardiac output has been known to increase in response to altered hemodynamics during states of increased oxygen demand. What is new: •  In the setting of septic shock induced by gram-negative organisms, echocardiographic parameters are less likely to assist in the assessment of the response to vasoactive agents. Cytokines, induced by gram-negative organisms, may alter adrenoreceptors in myocardium and vasculature.


Assuntos
Choque Séptico , Recém-Nascido , Humanos , Choque Séptico/diagnóstico por imagem , Choque Séptico/terapia , Ecocardiografia , Hemodinâmica , Débito Cardíaco/fisiologia , Ventrículos do Coração
11.
Sci Rep ; 14(1): 1671, 2024 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-38238507

RESUMO

There is no reliable automated non-invasive solution for monitoring circulation and guiding treatment in prehospital emergency medicine. Cardiac output (CO) monitoring might provide a solution, but CO monitors are not feasible/practical in the prehospital setting. Non-invasive ballistocardiography (BCG) measures heart contractility and tracks CO changes. This study analyzed the feasibility of estimating CO using morphological features extracted from BCG signals. In 20 healthy subjects ECG, carotid/abdominal BCG, and invasive arterial blood pressure based CO were recorded. BCG signals were adaptively processed to isolate the circulatory component from carotid (CCc) and abdominal (CCa) BCG. Then, 66 features were computed on a beat-to-beat basis to characterize amplitude/duration/area/length of the fluctuation in CCc and CCa. Subjects' data were split into development set (75%) to select the best feature subset with which to build a machine learning model to estimate CO and validation set (25%) to evaluate model's performance. The model showed a mean absolute error, percentage error and 95% limits of agreement of 0.83 L/min, 30.2% and - 2.18-1.89 L/min respectively in the validation set. BCG showed potential to reliably estimate/track CO. This method is a promising first step towards an automated, non-invasive and reliable CO estimator that may be tested in prehospital emergencies.


Assuntos
Balistocardiografia , Sistema Cardiovascular , Humanos , Estudos de Viabilidade , Voluntários Saudáveis , Débito Cardíaco/fisiologia , Frequência Cardíaca/fisiologia
12.
J Vis Exp ; (203)2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38284537

RESUMO

This protocol describes an acute volume overload porcine model for adult Yorkshire pigs and piglets. Both swine ages undergo general anesthesia, endotracheal intubation, and mechanical ventilation. A central venous catheter and an arterial catheter are placed via surgical cutdown in the external jugular vein and carotid artery, respectively. A pulmonary artery catheter is placed through an introducer sheath of the central venous catheter. PlasmaLyte crystalloid solution is then administered at a rate of 100 mL/min in adult pigs and at 20 mL/kg boluses over 10 min in piglets. Hypervolemia is achieved either at 15% decrease in cardiac output or at 5 L in adult pigs and at 500 mL in piglets. Hemodynamic data, such as heart rate, respiratory rate, end-tidal carbon dioxide, fraction of oxygen-saturated hemoglobin, arterial blood pressure, central venous pressure, pulmonary artery pressure, pulmonary capillary wedge pressure, partial arterial oxygen pressure, lactate, pH, base excess, and pulmonary artery fraction of oxygen-saturated hemoglobin, are monitored during experimentation. Preliminary data observed with this model has demonstrated statistically significant changes and strong linear regressions between central hemodynamic parameters and acute volume overload in adult pigs. Only pulmonary capillary wedge pressure demonstrated both a linear regression and a statistical significance to acute volume overload in piglets. These models can aid scientists in the discovery of age-appropriate therapeutic and monitoring strategies to understand and prevent acute volume overload.


Assuntos
Hemodinâmica , Respiração Artificial , Humanos , Adulto , Criança , Animais , Suínos , Débito Cardíaco/fisiologia , Oxigênio , Hemoglobinas
13.
Sci Rep ; 14(1): 2227, 2024 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-38278825

RESUMO

Fluid bolus therapy (FBT) is fundamental to the management of circulatory shock in critical care but balancing the benefits and toxicities of FBT has proven challenging in individual patients. Improved predictors of the hemodynamic response to a fluid bolus, commonly referred to as a fluid challenge, are needed to limit non-beneficial fluid administration and to enable automated clinical decision support and patient-specific precision critical care management. In this study we retrospectively analyzed data from 394 fluid boluses from 58 pigs subjected to either hemorrhagic or distributive shock. All animals had continuous blood pressure and cardiac output monitored throughout the study. Using this data, we developed a machine learning (ML) model to predict the hemodynamic response to a fluid challenge using only arterial blood pressure waveform data as the input. A Random Forest binary classifier referred to as the ML fluid responsiveness algorithm (MLFRA) was trained to detect fluid responsiveness (FR), defined as a ≥ 15% change in cardiac stroke volume after a fluid challenge. We then compared its performance to pulse pressure variation, a commonly used metric of FR. Model performance was assessed using the area under the receiver operating characteristic curve (AUROC), confusion matrix metrics, and calibration curves plotting predicted probabilities against observed outcomes. Across multiple train/test splits and feature selection methods designed to assess performance in the setting of small sample size conditions typical of large animal experiments, the MLFRA achieved an average AUROC, recall (sensitivity), specificity, and precision of 0.82, 0.86, 0.62. and 0.76, respectively. In the same datasets, pulse pressure variation had an AUROC, recall, specificity, and precision of 0.73, 0.91, 0.49, and 0.71, respectively. The MLFRA was generally well-calibrated across its range of predicted probabilities and appeared to perform equally well across physiologic conditions. These results suggest that ML, using only inputs from arterial blood pressure monitoring, may substantially improve the accuracy of predicting FR compared to the use of pulse pressure variation. If generalizable, these methods may enable more effective, automated precision management of critically ill patients with circulatory shock.


Assuntos
Pressão Arterial , Choque , Humanos , Suínos , Animais , Estudos Retrospectivos , Respiração Artificial/métodos , Ressuscitação/métodos , Débito Cardíaco/fisiologia , Hemodinâmica/fisiologia , Pressão Sanguínea , Volume Sistólico/fisiologia , Choque/terapia , Curva ROC
14.
Cardiol Young ; 34(2): 262-267, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37317547

RESUMO

BACKGROUND: Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. METHODS: Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. RESULTS: Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. CONCLUSIONS: Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.


Assuntos
Transplante de Coração , Imageamento por Ressonância Magnética , Criança , Humanos , Reprodutibilidade dos Testes , Cateterismo Cardíaco , Oximetria/métodos , Débito Cardíaco/fisiologia , Espectroscopia de Ressonância Magnética
15.
Ultrasound Obstet Gynecol ; 63(2): 198-205, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37325858

RESUMO

OBJECTIVE: Maternal cardiac function plays a crucial role in placental function and development. The maternal hemodynamic changes in twin pregnancy are more pronounced than those in singleton pregnancy, presumably due to a greater plasma volume expansion. In view of the correlation between maternal cardiac and placental function, it is plausible that chorionicity could influence maternal cardiac function. The aim of this study was to compare the longitudinal maternal hemodynamic changes between uncomplicated dichorionic (DC) and monochorionic (MC) twin pregnancies and in comparison to singleton pregnancies. METHODS: Included in the study were 40 MC diamniotic and 35 DC diamniotic uncomplicated twin pregnancies. These were compared with a group of 294 healthy singleton pregnancies from a previous cross-sectional study. All participants underwent a hemodynamic evaluation using an Ultrasound Cardiac Output Monitor (USCOM®), at three different stages in pregnancy (11-15 weeks, 20-24 weeks and 29-33 weeks). The following parameters were recorded: mean arterial pressure (MAP), stroke volume (SV), stroke volume index (SVI), heart rate, cardiac output (CO), cardiac index (CI), systemic vascular resistance (SVR), systemic vascular resistance index (SVRI), stroke volume variation, Smith-Madigan inotropy index (INO) and potential-to-kinetic-energy ratio (PKR). RESULTS: In the first trimester, DC and MC twin pregnancies showed lower MAP, SVR and PKR and higher CO and SV in comparison to singleton pregnancy. In the second trimester, maternal CO (8.33 vs 7.30 L/min, P = 0.03) and CI (4.52 vs 4.00 L/min/m2 , P = 0.02) were significantly higher in MC compared with DC twin pregnancy. In the third trimester, compared with in singleton pregnancy, women with MC twin pregnancy showed significantly higher PKR (24.06 vs 20.13, P = 0.03) and SVRI (1837.20 vs 1698.48 dynes × s/cm5 /m2 , P = 0.03), and significantly lower SV (78.80 vs 88.80 mL, P = 0.01), SVI (42.79 vs 50.31 mL/m2 , P < 0.01) and INO (1.70 vs 1.87 W/m2 , P = 0.03); these differences were not observed between DC twin and singleton pregnancies. CONCLUSIONS: Maternal cardiovascular function undergoes significant change during uncomplicated twin pregnancy and chorionicity influences maternal hemodynamics. In both MC and DC twin pregnancy, hemodynamic changes are detectable as early as the first trimester, showing higher maternal CO and lower SVR compared with singleton pregnancy. In DC twin pregnancy, the maternal hemodynamics remain stable during the rest of pregnancy. In contrast, in MC twin pregnancy, the rise in maternal CO continues in the second trimester in order to sustain the greater placental growth. There is a subsequent crossover, with a reduction in cardiovascular performance during the third trimester. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Placenta , Gravidez de Gêmeos , Gravidez , Feminino , Humanos , Gravidez de Gêmeos/fisiologia , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Gêmeos Dizigóticos
16.
ESC Heart Fail ; 11(1): 570-573, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37915262

RESUMO

The Fick principle is an established method to quantify intracardiac shunts. The Fick principle has also found utility in the practice of extracorporeal membrane oxygenation (ECMO). This report describes a novel 'shunt fraction' method to calculate intrinsic cardiac output in central (right atrial-to-aorta) ECMO. The physiological basis of this 'shunt fraction' method is described, followed by the case presentation that details the clinical application of this method of quantifying intrinsic cardiac output to guide weaning and liberation from central VA ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Débito Cardíaco/fisiologia , Coração
17.
J Appl Physiol (1985) ; 136(1): 141-150, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38031720

RESUMO

Posttraumatic stress disorder (PTSD) is associated with an increased risk of developing cardiovascular disease, especially in women. Evidence indicates that men with PTSD exhibit lower maximal oxygen uptake (V̇o2max) relative to controls; however, whether V̇o2max is blunted in women with PTSD remains unknown. Furthermore, it is unclear what determinants (i.e., central and/or peripheral) of V̇o2max are impacted by PTSD. Therefore, we evaluated the central (i.e., cardiac output; Q̇c) and peripheral (i.e., arteriovenous oxygen difference) determinants of V̇o2max in women with PTSD; hypothesizing that V̇o2max would be lower in women with PTSD compared with women without PTSD (controls), primarily due to smaller increases in stroke volume (SV), and therefore Q̇c. Oxygen uptake (V̇o2), heart rate (HR), Q̇c, SV, and arteriovenous oxygen difference were measured in women with PTSD (n = 14; mean [SD]: 43 [11] yr,) and controls (n = 17; 45 [11] yr) at rest, and during an incremental maximal treadmill exercise test, and the Q̇c/V̇o2 slope was calculated. V̇o2max was not different between women with and without PTSD (24.3 [5.6] vs. 26.4 [5.0] mL/kg/min; P = 0.265). However, women with PTSD had higher Q̇c [P = 0.002; primarily due to greater SV (P = 0.069), not HR (P = 0.285)], and lower arteriovenous oxygen difference (P = 0.002) throughout exercise compared with controls. Furthermore, the Q̇c/V̇o2 slope was steeper in women with PTSD relative to controls (6.6 [1.4] vs. 5.7 [1.0] AU; P = 0.033). Following maximal exercise, women with PTSD exhibited slower HR recovery than controls (P = 0.046). Thus, despite attenuated peripheral oxygen extraction, V̇o2max is not reduced in women with PTSD, likely due to larger increases in Q̇c.NEW & NOTEWORTHY The current study indicates that V̇o2max is not different between women with and without PTSD; however, women with PTSD exhibit blunted peripheral extraction of oxygen, thus requiring an increase in Q̇c to meet metabolic demand during exercise. Furthermore, following exercise, women with PTSD demonstrate impaired autonomic cardiovascular control relative to sedentary controls. We interpret these data to indicate that women with PTSD demonstrate aberrant cardiovascular responses during and immediately following fatiguing exercise.


Assuntos
Transtornos de Estresse Pós-Traumáticos , Masculino , Humanos , Feminino , Consumo de Oxigênio/fisiologia , Débito Cardíaco/fisiologia , Volume Sistólico/fisiologia , Frequência Cardíaca/fisiologia , Teste de Esforço , Oxigênio/metabolismo
18.
Curr Opin Organ Transplant ; 29(1): 72-81, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38032246

RESUMO

PURPOSE OF REVIEW: The purpose of this article is to provide a comprehensive review of hemodynamic monitoring in liver transplantation. RECENT FINDINGS: Radial arterial blood pressure monitoring underestimates the aortic root arterial blood pressure and causes excessive vasopressor and worse outcomes. Brachial and femoral artery monitoring is well tolerated and should be considered in critically ill patients expected to be on high dose pressors. The pulmonary artery catheter is the gold standard of hemodynamic monitoring and is still widely used in liver transplantation; however, it is a highly invasive monitor with potential for serious complications and most of its data can be obtained by other less invasive monitors. Rescue transesophageal echocardiography relies on few simple views and should be available as a standby to manage sudden hemodynamic instability. Risk of esophageal bleeding from transesophageal echocardiography in liver transplantation is the same as in other patient populations. The arterial pulse waveform analysis based cardiac output devices are minimally invasive and have the advantage of real-time beat to beat monitoring of cardiac output. No hemodynamic monitor can improve clinical outcomes unless integrated into a goal-directed hemodynamic therapy. The hemodynamic monitoring technique should be tailored to the patient's medical status, surgical technique, and the anesthesiologist's level of expertise. SUMMARY: The current article provides a review of the current hemodynamic monitoring systems and their integration in goal-directed hemodynamic therapy.


Assuntos
Monitorização Hemodinâmica , Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Monitorização Fisiológica/métodos
19.
Eur Radiol ; 34(3): 1825-1835, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37650970

RESUMO

OBJECTIVES: Left ventricle function directly impacts left atrial (LA) conduit function, and LA conduit strain is associated with exercise intolerance in patients with heart failure with preserved ejection fraction (HFpEF). Pulmonary capillary wedge pressure (PCWP) before and during exercise is the current gold standard for diagnosing HFpEF. Post-exercise ΔPCWP can lead to worse long-term outcomes. This study examined the correlation between LA strain and post-exercise ΔPCWP in patients with HFpEF. METHODS: We enrolled 100 subjects, including 74 with HFpEF and 26 with non-cardiac dyspnea, from November 2017 to December 2020. Subjects underwent echocardiography, invasive cardiac catheterization, and expired gas analysis at rest and during exercise. Arterial blood pressure, right atrial pressure, pulmonary artery pressure, and PCWP were recorded during cardiac catheterization. Cardiac output, stroke volume, pulmonary vascular resistance, pulmonary artery compliance, systemic vascular resistance, and LV stroke work were calculated using standard formulas. RESULTS: Exercise LA conduit strain significantly correlated with both post-exercise ΔPCWP (r = - 0.707, p < 0.001) and exercise PCWP (r = - 0.659; p < 0.001). Exercise LA conduit strain differentiated patients who did and did not meet the 2016 European Society of Cardiology HFpEF criteria with an area under the curve of 0.69 (95% confidence interval, 0.548-0.831) using a cutoff value of 14.25, with a sensitivity of 0.64 and a specificity of 0.68. CONCLUSIONS: Exercise LA conduit strain significantly correlates with post-exercise ΔPCWP and has a comparable power to identify patients with HFpEF. Additional studies are warranted to confirm the ability of LA conduit strain to predict long-term outcomes among patients with HFpEF. CLINICAL RELEVANCE STATEMENT: Exercise left atrial conduit strain was highly associated with the difference of post-exercise pulmonary capillary wedge pressure and may indicate increased mortality risk in patients with heart failure with preserved ejection fraction, and also has comparable diagnostic ability. KEY POINTS: • Left atrial conduit strain is associated with exercise intolerance in patients with heart failure with preserved ejection fraction. • Left atrial conduit strain during exercise can identify patients with heart failure with preserved ejection fraction. • Exercise left atrial conduit strain significantly correlates with the difference of pulmonary capillary wedge pressure during and before exercise which might predict the long-term outcomes of heart failure with preserved ejection fraction patients.


Assuntos
Insuficiência Cardíaca , Humanos , Volume Sistólico/fisiologia , Hemodinâmica , Débito Cardíaco/fisiologia , Pressão Propulsora Pulmonar/fisiologia , Função Ventricular Esquerda/fisiologia
20.
Sleep Med ; 113: 25-33, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37979504

RESUMO

BACKGROUND: Noninvasive positive pressure ventilation (NIPPV) has been established as an effective treatment for heart failure. Positive airway pressure such as continuous positive airway pressure (CPAP) increases cardiac output (CO) in some patients but decreases it in others. However, the mechanism behind such unpredictable responses remains undetermined. METHODS AND RESULTS: We measured hemodynamic parameters of 38 cases using Swan-Ganz catheter before and after CPAP in chronic heart failure status. In those whose CO increased by CPAP, pulmonary vascular resistance (PVR) was significantly decreased and SpO2 significantly increased, but the other parameters were not changed. On the other hand, PVR was not changed, but systemic vascular resistance (SVR) was increased in those whose CO decreased by CPAP. To explain this phenomenon, we simulated the cardiovascular system using a cardiac model of time-varying elastance. In this model, it was indicated that CPAP decreases CO irrespective of cardiac function or filling status under constant PVR condition. However, when reduction of PVR by CPAP was taken into account, an increase in CO was expected especially in the hypervolemic and low right ventricle (RV) systolic function cases. CONCLUSIONS: CPAP would increase CO only where PVR can be reduced by CPAP therapy, especially in the case with hypervolemia and/or low RV systolic function. Understanding the underlying mechanism should help identify the patients for whom NIPPV would be effective.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Insuficiência Cardíaca , Humanos , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Coração , Insuficiência Cardíaca/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...